fiber optix logo

SC Series Fiber Optic Connectors

The iFiber Optix SC Series Fiber Optic Connectors are engineered to provide secure, efficient, and high-performance connections across the full spectrum of contemporary fiber optic networks. Featuring a push-pull latching mechanism for quick, tool-free installation and a Physical Contact (PC) polish for low insertion loss and minimal back reflection, SC connectors remain one of the most widely deployed fiber optic connector types in the world.

Compliant with ANSI, IEC, TIA/EIA, and RoHS standards and available for both singlemode and multimode fiber, iFiber Optix SC Series connectors deliver the reliability, durability, and optical precision that telecommunications networks, data centers, and enterprise infrastructures demand.

iFiber Optix SC Series Fiber Optic Connectors

SC Series Fiber Optic Connectors

The SC (Subscriber Connector) features a robust push-pull latching body that snaps securely into place and releases cleanly with a single motion — no threading, no tools, no accidental disconnections. With a 2.5mm ceramic ferrule in Physical Contact (PC) configuration, SC connectors deliver low insertion loss, high return loss, and consistent optical alignment across thousands of mating cycles. Available for OS1/OS2 singlemode and OM1–OM4 multimode fiber applications.

Download Product Datasheet

Key Features

  • Push-Pull Latching Mechanism The SC connector's push-pull latch provides quick, positive insertion and clean single-motion removal — no threading required. This design eliminates the risk of accidental disconnection while dramatically reducing installation and maintenance time compared to threaded connectors.
  • Physical Contact (PC) Polish The PC ferrule end-face ensures direct glass-to-glass contact, delivering low insertion loss and reduced back reflection for reliable, high-quality signal transmission across both singlemode and multimode fiber applications.
  • Low Insertion Loss Insertion loss of ≤ 0.15dB typical for singlemode and ≤ 0.20dB typical for multimode, maintaining efficient signal transmission and maximizing available link budget across the full fiber span.
  • High Return Loss Return loss of ≥ 55dB PC for singlemode connections, minimizing reflected optical power and protecting upstream transmitters and transceivers from back-reflection interference.
  • High Durability & Reliability Durability rated at <0.1dB change over the full rated mating cycle count, with a wide operating temperature range of -40°C to +75°C — designed for long-term performance across diverse environmental conditions.
  • Industry Standards Compliance Fully compliant with ANSI, IEC, TIA/EIA, and RoHS standards, ensuring compatibility with existing infrastructure, safety in regulated environments, and acceptance across international network deployments.

Technical Specifications

All iFiber Optix SC Series connectors are manufactured and tested to meet or exceed the following performance specifications.

Specification Singlemode Multimode
Insertion Loss ≤ 0.15dB typical ≤ 0.20dB typical
Return Loss ≥ 55dB PC
Durability < 0.1dB change over rated cycles < 0.1dB change over rated cycles
Operating Temperature -40°C to +75°C -40°C to +75°C
Connector Type SC (Subscriber Connector), push-pull latch, 2.5mm ceramic ferrule
Polish Type PC (Physical Contact)
Fiber Compatibility OS1 / OS2 (9/125µm) OM1 / OM2 / OM3 / OM4
Standards ANSI, IEC, TIA/EIA, RoHS

Example use case: OS2 singlemode SC/PC connector deployed on a campus backbone link between two IDF closets — delivering ≥ 55dB return loss and ≤ 0.15dB insertion loss per connection with tool-free push-pull installation across a 24-port patch panel.

Applications

SC connectors are among the most universally deployed fiber optic connector types — found across telecommunications, enterprise, and data center infrastructure worldwide.

Telecom

Telecommunications Networks

Ideal for high-speed data transmission in telecom central offices, distribution frames, and long-haul fiber infrastructure — where the SC's large body and positive latch make it easy to manage in dense patch environments.

Data Centers

Data Centers

Suitable for high-density fiber optic panel connections in data centers, supporting efficient singlemode and multimode patch cord management across server rows, top-of-rack switches, and core distribution frames.

Enterprise Networks

Enterprise Networks

Perfect for internal LAN, WAN, and backbone cabling in office buildings and campuses — where the SC's ease of installation simplifies moves, adds, and changes in structured cabling environments.

FTTH / FTTB

Fiber to the Home

Widely used in FTTH and FTTB optical network terminals (ONT) and distribution points, providing reliable singlemode connections for residential and commercial last-mile fiber deployments.

Broadcast & AV

Broadcast & AV Systems

SC connectors are a common choice in broadcast and professional AV fiber infrastructure — where singlemode fiber carries video and control signals over longer campus or facility distances.

Legacy & Retrofit

Legacy Infrastructure

SC remains one of the most prevalent installed connector types globally. iFiber Optix SC Series connectors provide fully compatible replacements and extensions for existing SC-based infrastructure without requiring costly adapter panels.

How to Choose the Right SC Connector

SC connectors are available for a range of fiber types and applications — use this guide to confirm the correct configuration for your deployment.

01

Select Fiber Type

OS1/OS2 singlemode for long-distance or high-bandwidth backbone and telecom links. OM1–OM4 multimode for shorter-reach connections within buildings or data center rows where SC is already the installed connector type.

02

Confirm Simplex or Duplex

SC connectors are available in both simplex (single fiber) and duplex (two-fiber side-by-side) configurations. Most transceiver equipment using SC interfaces requires duplex — verify your equipment specifications before ordering.

03

PC vs. UPC vs. APC

SC/PC is the standard configuration for most digital applications. SC/UPC provides slightly improved return loss for high-performance digital links. SC/APC (green, angled ferrule) is required for analog, CATV, and DWDM systems where back reflection must be virtually eliminated.

04

SC vs. LC for New Deployments

For new high-density installations, LC connectors offer a smaller footprint and higher port density. SC remains the correct choice when matching existing SC infrastructure, when larger connector bodies aid technician handling, or when equipment specifies SC interfaces.

Why Choose iFiber Optix for SC Connectors?

  • Quality Assurance Every SC connector is manufactured to meet stringent industry standards and undergoes precision optical testing before shipment — ensuring optimal insertion loss, return loss, and mechanical performance right out of the box.
  • Ease of Use The push-pull latch design allows for quick, secure connections and clean single-motion removal — simplifying installation, maintenance, and routine moves and changes across patch panels and equipment ports.
  • Versatility Suitable for a wide range of applications, from long-haul telecommunications and FTTH to data centers and enterprise LANs — across both singlemode and multimode fiber types and a full range of cable jacket options.
  • Custom Configurations Available Custom cable lengths, jacket materials (PVC, plenum, LSZH, armored), polish types, and connector configurations available — manufactured to your exact project specifications for seamless integration into any new or existing infrastructure.

iFiber Optix SC Series Fiber Optic Connectors deliver the reliability, ease of use, and optical precision that modern networks demand. Whether you need standard singlemode or multimode SC patch cords, bulk connector assemblies, or a fully custom-engineered solution, our team is ready to help you specify and source the right product for your infrastructure.