SC-FC/APC Singlemode Ultra Fiber Optic Cable
The iFiber Optix SC/APC-FC/APC Singlemode Ultra Fiber Cable is built for high-performance connectivity in telecom, data center, and enterprise environments that require low-loss, high-reliability optical transmission.
Featuring Corning SMF-28 Ultra Optical Fiber and precision APC connectors on both ends, this cable is designed to deliver excellent signal integrity and dependable operation over long distances.
SC/APC-FC/APC Singlemode Ultra Fiber Cable
The SC/APC-FC/APC Singlemode Ultra Fiber Cable combines the secure and widely used SC/APC connector with a precision FC/APC connector for low-loss, high-return-loss performance. Its singlemode fiber construction is well suited for long-distance optical transmission where signal quality matters most.
This cable is a strong fit for telecommunications, data centers, and industrial installations that need dependable, high-precision fiber connectivity.
Performance Specifications
All iFiber Optix SC/APC-FC/APC singlemode assemblies are manufactured and tested to meet or exceed the following optical and mechanical performance specifications.
| Insertion Loss | 0.3 dB |
| Typical Insertion Loss | 0.15 dB |
| Back Reflection | < -55 dB |
| Back Reflection (Typical) | < -65 dB |
| Temperature Range | -40°C to 85°C |
| Connector Type | SC/APC to FC/APC Duplex |
| Fiber Core / Cladding | 8.33 / 125µm |
| Part Number | I2750-D-XX-XJ |
| Return Loss | ≥ 60 dB |
| Insertion Loss | < 0.3 dB |
Key Features
- Reliable Performance Stable optical transmission supports critical network environments that require consistent, low-loss connectivity.
- Low Insertion Loss With insertion loss below 0.3 dB, the cable helps preserve signal strength over long runs.
- High Return Loss The APC-polished connectors help reduce back reflection and improve signal integrity.
- Durable Construction Built to meet SPC GR-326 geometric requirements for long-term reliability and precision termination.
- Secure Dual APC Design Both ends use angled physical contact polishing to support low-reflection, precision optical links.
Ideal Applications
SC/APC-FC/APC singlemode cables are commonly used where low-loss precision and secure optical connections are both important.
Telecommunications
Ideal for long-distance optical links in telecom networks.
Data Centers
Supports high-density optical environments that require low-loss connectivity.
Industrial Networks
Useful in rugged environments where durable fiber performance matters.
Network Backbones
Well suited for backbone runs and inter-building connections.
Test and Measurement
Appropriate for optical testing and precision lab setups.
Custom Fiber Builds
Available in custom lengths and configurations for specialized deployments.
How to Choose the Right SC/APC-FC/APC Configuration
Use these considerations to match the cable to your network needs.
Confirm Distance Requirements
Select singlemode when your installation requires long-range transmission and low attenuation.
Check Connector Compatibility
Verify that both ends match your hardware and that the SC and FC/APC terminations fit your system.
Match the Environment
Choose the correct jacket and build style for indoor, outdoor, or mixed-use deployments.
Plan for Routing Needs
Pick a cable length and diameter that support clean routing and reliable termination.
Why Choose iFiber Optix?
- Quality Assurance Each cable is built and tested for consistent optical performance before shipment.
- Custom Configurations Lengths, jackets, and connector options can be tailored to your project.
- Reliable Support Our team can help you choose the right fiber solution for telecom, data center, or industrial use.
- Built for Critical Deployments Designed to deliver dependable long-distance connectivity in demanding network environments.
Request Information
Ready to spec SC/APC-FC/APC singlemode cables for your next deployment? Our team can help with custom lengths, jacket selection, and bulk pricing.
