Mode Condition Patch Cord
Description
The
Mode Conditioning Patch Cord is designed for long wave (-LX) multimode
applications of Gigabit Ethernet.
It is compliant with this IEEE 802.3z application standard.
This patch cord consist of duplex SC connectors on each end of
a cable assembly with a single-mode fiber offset to a multimode fiber
connection in one of the two legs.
The need for this patch cord is due to the single-mode
launch nature of the LX or long-wave (1300nm) transceiver modules
used for Gigabit Ethernet. These modules have to operate with both
single-mode and multimode fibers.
Launching the single-mode laser into the center of a multimode
fiber can cause multiple signals to be generated that confuse the receiver
at the other end of the fiber.
These multiple signals, caused by Differential Mode Delay (DMD)
effects, severely limit the cable distance lengths for operating Gigabit
Ethernet. A mode conditioning
patch cord eliminates these multiple signals by allowing the single-mode
launch to be offset away from the center of a multimode fiber.
Offset point creates a launch that is similar to typical multimode
LED from the center of a multimode fiber.
This offset point creates a launch that is similar to typical multimode
LED launches.
Features
- IEEE-802z
(Gigabit Ethernet) Compliant)
- Permanent
offset closure
- Low
profile offset closure
- Low
loss
- Fits
existing cabling scheme
- Easy
to use
Benefits
- Avoids
Different Mode Delay (DMD) signal
- Correct
offset always maintained
- Aesthetically
pleasing
- Uses
precision ceramic ferrules
- Use
in place of standard equipment-to-cable plant patch cord
- Functions
the same as standard patch cord
Specifications
Attenuation
<0.5 dB
Reflectance
<26 dB
Ordering Information
These patch cords are available in a variety
of lengths and can be ordered by the following part number scheme:
| Part Number |
|
Description |
| I1048-A-XXM |
|
SC/SC
to (SC Duplex, Equipment Side), riser, 62.5mm |
| I1048-A5-XXM |
|
SC/SC
to (SC Duplex, Equipment Side), riser, 50mm |
| I1048-AP-XXM |
|
SC/SC
to (SC Duplex, Equipment Side), plenum, 62.5mm |
| I1048-BP-XXM |
|
SC/SC
to (SC Duplex, Equipment Side), plenum, 50mm |
| I1048-C-XXM |
|
STŪ
compatible/ST compatible to (SC Duplex, Equipment side) riser 62.5mm |
| I1048-C5-XXM |
|
STŪ
compatible/ST compatible to (SC Duplex, Equipment side) riser 50mm |
| I1048-CP-XXM |
|
STŪ
compatible/ST compatible to (SC Duplex, Equipment side) plenum 62.5mm |
| I1048-C5P-XXM |
|
STŪ
compatible/ST compatible to (SC Duplex, Equipment side) plenum 50mm |
| . |
| The
M specifies lengths in meter |
| Example: For a 3 meter,
SC/SC, riser, 62.5 mm patch cord, the part number is
I1048-A-03M |
|